The production cost of cylindrical tank shell depending on the sort of steel and metal plate dimensions
(International Conference on CARRYIG CAPACITY OF STEEL SHELL STEUCTURES, 1-3 October 1997, Brno, Czech Republic, 1997-10)
The results of an economic analysis, comprising approximately 350 types of shells made for tanks of nominal capacity ranging from 50 - , 80-, 100.000 m3 in view of the sort of constructional steel and overall dimensions ...
Correctness of work execution in tank construction in statistics
(2000-09-27)
The results of a statistical analysis related to preliminary values and their later geometrical imperfections deveIoped in course of the operationaI use of large capacity tank structures made in recent years are presented. ...
The Structure of the Tank Having Capacity V=75.000 m3 with Double Wall and Bottom
(International Colloquium - New Decisions in Designing and Building of Metallic Tnaks. International Association for Shell and Spatial Structures IASS. Working Group 1. Tanks and Silos, 2000-06-13)
A design for an oil tank of 75 000 m3 capacity has been discussed. The tank is an
ecologically safe object with respect to its use of a double shell and a double bottom with a monitoring system of some possible leakages.
Konstrukcja zbiornika o pojemności V=75000 m3 dwupłaszczowego i z podwójnym dnem
(Konferencja Naukowo - Techniczna "Problemy eksploatacyjne baz magazynowych produktów naftowych", Centrum Edukacji "ALIAS", Poznań, 2000, 2000-05-15)
Przedstawiono budowę nowozaprojektowanego zbiornika magazynowego o pojemności V=75 000 m3 przeznaczonego do magazynowania paliw płynnych. Zbiornik został zaprojektowany jako dwupłaszczowy i dwudenny z pływającym dachem ...
Distribution of stresses into steel tank shells induced by executive errors
(Latest Advances in Tank Construction Including Problems of Earthquake Resistance'' Moscow State Building University - International Association for Shells and Spatial Structures - IASS - Working group 1 - "Tanks and Silos'', Moscow State Building University. Moskwa, 1999, 1999-10-12)
Reasons for the arising of defects in shells of steel storage tallk uроn its рrоduсtion and erection are considered оп the example of steel tank with volume 50 000 м3 recently built in Poland. Exact саlculations confirm ...
Analizy numeryczne powłok walcowych z imperfekcjami kształtu
(Wydział Inżynierii Lądowej i Środowiska Politechniki Gdańskiej, 2005-09-12)
W artykule przedstawiono wyniki analiz numerycznych cylindycznych powłok z regularnymi imperfekcjami geometrycznymi. Wyniki przedstawiono dla powłok o promieniu zakrzywienia R=10 i 30 m. Zostały zaprezentowane wyniki dla ...
Tank construction of 75 000 m3 capacity with double shell and double bottom
(C-PRESS, 2000-09-27)
A design for an oil tank of 75 000 m3 capacity has been discussed. The tank is an
ecologically safe object with respect to its use of a double shell and a double bottom with a monitoring system of some possible leakages. ...
Badania tensometryczne stalowych płaszczy zbiorników z imperfekcjami kształtu
(Xth International Scientific-Technical Conference ''Metal structures - Gdańsk 2001''. Gdańsk, 6-8.06.2001, 2001-06-06)
PL: W referacie przestawiono wyniki pomiarów tensometrycznych zmienności naprężeń w powłoce z deformacjami kształtu. Pomiary przeprowadzono na płaszczu zbiornika stalowego na paliwa płynne, o pojemności V=12.000 m3, ...
Jakościowa i ilościowa ocena odchyłek wykonania płaszczy zbiorników stalowych
(Konferencja: Problemy eksploatacyjne baz magazynowych produktów naftowych - Centrum Edukacji ALIAS, Poznań, 1999,, 1999-05-10)
W opracowaniu przedstawiono wyniki opracowań statystycznych dotyczących rozkładu imperfekcji geometrycznych płaszczy zbiorników magazynowych z dachami pływającymi, służącymi do przechowywania surowej ropy naftowej.
Zastosowanie lekkich konstrukcji stalowych do renowacji, rozbudowy i remontów obiektów budowlanych
(XXIII Ogólnopolska Konferencja WARSZTAT PRACY PROJEKTANTA KONSTRUKCJI, Polski Związek Inżynierów i Techników Budownictwa Oddział w Katowicach, 2008-03-05)