Szukaj
Wyświetlanie pozycji 11-15 z 15
Badania tensometryczne płaszcza zbiornika z imperfekcjami kształtu
(Dolnośląskie Wydawnictwo Edukacyjne, 2004)
PL: W referacie przedstawiono wykorzystanie tensometrycznej metody pomiaru odkształceń do oceny rozkładu naprężeń powierzchniowych w konstrukcji powłoki rzeczywistego obiektu. Obiektem poddanym polowym badaniom był stalowy ...
Stesses in tank shell with shape deformation
(International Conference "DESIGN, INSPECTION, MAINTENANCE AND OPERATION OF CYLINDRICAL STEEL TANKS AND PIPELINES" Prague, 2003, 2003-10-08)
In the paper are shown the results of measurements of stress state in the real tank. The tests were performed with the utilisation of electroresistant tensometry methods. The object of the tests was a vertical tank with ...
The Structure of the Tank Having Capacity V=75.000 m3 with Double Wall and Bottom
(International Colloquium - New Decisions in Designing and Building of Metallic Tnaks. International Association for Shell and Spatial Structures IASS. Working Group 1. Tanks and Silos, 2000-06-13)
A design for an oil tank of 75 000 m3 capacity has been discussed. The tank is an
ecologically safe object with respect to its use of a double shell and a double bottom with a monitoring system of some possible leakages.
The production cost of cylindrical tank shell depending on the sort of steel and metal plate dimensions
(International Conference on CARRYIG CAPACITY OF STEEL SHELL STEUCTURES, 1-3 October 1997, Brno, Czech Republic, 1997-10)
The results of an economic analysis, comprising approximately 350 types of shells made for tanks of nominal capacity ranging from 50 - , 80-, 100.000 m3 in view of the sort of constructional steel and overall dimensions ...
Correctness of work execution in tank construction in statistics
(2000-09-27)
The results of a statistical analysis related to preliminary values and their later geometrical imperfections deveIoped in course of the operationaI use of large capacity tank structures made in recent years are presented. ...